You need flash player and javascript enabled to view this content

Get Adobe Flash player

 ICS Impulse - Video Head Impulse Testing device 

More than two decades of testing

ICS Impulse is the first and only HIT system to be approved by Drs. Michael Halmagyi and Ian Curthoys, whose groundbreaking work first brought HIT to the attention of the world in 1988. Having developed both the prototype and the algorithms, Drs. Halmagyi and Curthoys were highly qualified to test and evaluate Otometrics’ ICS Impulse. Their consensus was that it did indeed optimise their findings, providing thorough, precise results and excellent documentation.

Overview 
 

 

Unsurpassed diagnostic precision in less than 10 minutes

In addition to providing an accurate, objective measure of the vestibulo-ocular reflex, the ICS Impulse allows clinicians to test patients with spontaneous nystagmus. Both overt and covert saccades can be detected allowing for proper diagnosis and rehabilitation recommendations. The vestibular function of both ears can be assessed and documented in less than 10 minutes from patient entry to reporting.

In addition to providing an accurate, objective measure of the vestibulo-ocular reflex, the ICS Impulse allows clinicians to test patients with spontaneous nystagmus. Both overt and covert saccades can be detected allowing for proper diagnosis and rehabilitation recommendations. The vestibular function of both ears can be assessed and documented in less than 10 minutes from patient entry to reporting.

What is Head Impulse Testing?

An ear-specific test that detects disorders of the vestibulo-ocular reflex and identifies which ear is affected in cases of peripheral vestibular loss. Patients with a vestibular loss will exhibit a corrective saccadic eye movement (a “catch-up” saccade) either during or after the head impulse and the gain of the head in comparison to the eye will not be equivalent.


Features 
 

High speed camera (250 Hz)

  • Ultra-sensitive, requiring head turns of just 15°
  • Records fast eye movements that allow for identification of overt and covert saccades
  • Test takes less than 10 minutes from patient entry to reporting

Built-in gyroscopes

  • Ensure accurate head velocity measurement
  • Provide instant feedback on proper head impulse manoeuvre
  • Compare head and eye movement to assess VOR gain

Built-in calibration lasers

  • Calibration is quick and easy, using two lasers incorporated into the goggle itself
  • No need for additional hardware
  • Test can be performed anywhere

Built-in head impulse algorithms

  • Developed by HIT pioneers Drs. Michael Halmagyi an Ian Curthoys
  • Inaccurate head impulse data is automatically discarded
  • Only accurate data is analysed

Plug-and-go solution

  • Small and compact for ultimate portability
  • Easy and efficient for bedside testing
  • Enables accurate testing of immobile patients
Photos 
 
/SiteCollectionImages/ProductImages/impulseGoggles600.png
/SiteCollectionImages/ProductImages/impulse600.png